The U value of a 50mm foam board depends on the foam type and its density, but for most rigid foam boards it falls between roughly 0.5 and 1.0 W/m²K. That number tells you how much heat passes through each square meter of board per degree of temperature difference. Lower is better for insulation.
Why the U Value Isn’t a Single Number
Different foam materials insulate differently. A 50mm sheet of extruded polystyrene (XPS) typically has a lower U value than a 50mm sheet of expanded polystyrene (EPS) of the same density. Polyurethane and polyisocyanurate boards often insulate better per millimeter than either. The exact U value also changes with the board’s density, the facing material (foil, plastic, or paper), and how the board is installed.
You’ll find the U value printed on the product label or in the manufacturer’s data sheet. If it’s not there, look for the thermal conductivity (lambda value) and divide it by the thickness in meters. That calculation gives you the U value for the board alone. For example, a lambda of 0.035 W/mK divided by 0.05m gives 0.7 W/m²K.
Common Misconception: Thicker Always Means Better
People often assume that a 50mm board has a fixed U value, like a universal rating. That’s not true. The U value is a property of the whole assembly—the board plus any air gaps, fixings, and adjacent layers. A 50mm board with a foil facing can perform differently from the same foam without a facing, because the foil reflects radiant heat.
The correct way to think about it: the U value of the board is a starting point. The actual thermal performance of your wall, floor, or roof depends on how you install it. Gaps, compression, and thermal bridges (like metal fixings) can all increase the overall U value of the finished structure.
What to Look For on the Label
When you buy foam board, check the label for two numbers: the thermal conductivity (lambda) and the declared U value at the board’s thickness. The lambda value is the material’s intrinsic ability to conduct heat, and it’s the same regardless of thickness. The U value is calculated from lambda divided by thickness, so it gets lower as the board gets thicker.
If the label only gives lambda, you can do the math yourself. Just remember to convert the thickness to meters (50mm is 0.05m). If you’re comparing boards, compare their lambda values—lower lambda means better insulation per millimeter.
How to Use the U Value in Real Life
For a typical home insulation project, you’ll want to know the U value of the whole wall or roof, not just the board. Building regulations in many countries set maximum U values for different parts of a building, and your local authority will tell you what target you need to hit. The foam board’s U value is one component; the other layers (plasterboard, brick, timber, air gaps) also contribute.
To estimate the overall U value, you can use online U value calculators or ask your building materials supplier for a calculation. They’ll need the thickness and lambda of each layer, plus the type of construction. If you’re just comparing two boards for the same job, the lower U value at the same thickness is the better insulator.
Practical Rule of Thumb for Choosing
As a rough guide, for a 50mm board:
- Polyurethane (PUR) and polyisocyanurate (PIR) boards usually have the lowest U values, often below 0.7 W/m²K.
- Extruded polystyrene (XPS) is next, typically around 0.7 to 0.9 W/m²K.
- Expanded polystyrene (EPS) is usually the highest, often above 0.8 W/m²K.
These are general ranges, not guarantees. Always check the specific product’s data sheet. If you’re insulating a floor, a board with a higher compressive strength (like XPS) might be better even if its U value is slightly higher than a softer board. For walls, the facing and moisture resistance matter more.
What About the R Value?
You might see R value instead of U value. They’re reciprocals: R = 1/U. So a U value of 0.7 W/m²K corresponds to an R value of about 1.43 m²K/W. In the US, R values are often given in imperial units, which are different numbers. If you’re comparing products from different countries, make sure you’re using the same unit system.
For a 50mm board, the R value is simply the thickness divided by lambda. Again, lower lambda means higher R. It’s the same information, just flipped.
Installation Mistakes That Ruin the U Value
Even a perfect board won’t perform if it’s installed badly. The most common mistake is leaving gaps between boards—air can circulate and carry heat around the insulation. Seal joints with tape or foam sealant designed for the board type. Another mistake is compressing the board too much when fixing it, which reduces its thickness and increases the U value. And don’t forget to account for fixings like screws or nails that penetrate the board; they create thermal bridges.
If you’re using foil-faced boards, the foil should face the warm side of the building in most climates to reflect heat back. Check the manufacturer’s guidance for your specific product and climate.
Where to Find the Exact Figure You Need
For a specific product, look for the European CE marking or the manufacturer’s declaration. It will list the declared thermal conductivity and the U value at the board’s thickness. If you can’t find it online, contact the manufacturer or your supplier and ask for the technical data sheet. They should provide it free.
Remember, the U value of the board alone is rarely the final answer. For a building project, you need the whole assembly’s U value. Your building control officer or a qualified energy assessor can help you calculate it correctly.